Suffix codes

On product pages you will find suffix codes for specific functions. Combine the luminaire’s catalogue numbers with the required suffix code. Note that only one suffix code is possible.

Please contact customer service for your local market, if you need to combine several functions.

Suffix code HF-dim DALI

  • -223 DALI.
  • -368 DALI/Phase-pulse control. Make independent. No special functions defined.
  • -299 Excel one4all. DALI, DSI, switchDIM, SmartDim sensor, corridor function, programmable memory function ”E-power” (Power on last level).
  • -400 iDim HF-ballast. DALI, Switchcontrol, programmable memory function ”Power on last level”.
  • -402 DALI for dimmable LED driver.
Due to luminaire design additional code varies for the same function.
  • -436 DALI/DSI/switchDIM. TRIDONIC PCA BASIC ballast for dimming 10–100 % .

Suffix code HF-dim phase pulse control

  • -409 Phase pulse control, 1 pull switch. Make independent.
  • -410 Phase pulse control, 2 pull switches. Make independent.

Suffix code HF-dim 1–10 V

  • -61 1–10 V
  • -81 1–10 V
  • -205 1–10 V. Make independent.
Due to luminaire design additional code varies for the same function.

Suffix code Fagerhult e-Sense

  • -367 e-Sense ActiLume master luminaire. Sensor installation in the luminaire body. Master luminaire suitable for e.g. classrooms.
  • -382 e-Sense ActiLume master luminaire. Sensor installation in the Beta louvre. Master luminaire suitable for e.g. classrooms.
  • -384 e-Sense ActiLume single luminaire. Sensor installation in the luminaire body. 1 pull switch for dimming.
  • -385 e-Sense ActiLume single luminaire. Sensor installation in the Beta louvre. 1 pull switch for dimming.
  • -217 e-Sense ActiLume with DALI ballast for installation in the luminaire body. Terminal blocks for DALI 1 & DALI 2 outlets. In pendent luminaires equipped with 1 pull switch for dimming.
  • -218 e-Sense SmartSwitch absence damping for installation in the luminaire body, dimmable HF-ballast, 4-way terminal block for through-wiring of the control signal.
  • -309 As above but for sensor installation in the Beta louvre.
  • -219 e-Sense SmartSwitch on/off for installation in the luminaire body. (HF-ballast, i.e. only on/off =presence detector)
  • -314 As above but for sensor installation in the Beta louvre.
  • -220 e-Sense SmartSwitch for installation in the body, dimmable HF-ballast. Dimming via pull switch for dimming in pendant luminaires. 1 switch (1 ballast) for 1 and 2 lamp luminaires, 2 switches (2 ballasts) for 3 lamp luminaires.
  • -315 As above but for sensor installation in the Beta louvre.
  • -442 e-Sense ActiLume single luminaire with LED driver. Sensor installation in the luminaire body. 1 pull switch for dimming.

Suffix code e-Sense Connect

  • -426 Luminaire with integrated e-Sense Connect unit on/off only.
  • -427 Luminaire with integrated e-Sense Connect unit for dimming.
  • -428 Luminaire with integrated sensor and e-Sense Connect unit for dimming.

Suffix code e-Sense Detect

  • -357 e-Sense Detect on/off. Five slave luminaires can be connected.
  • -358 e-Sense Detect with absence dampening for FDH. More slave luminaires can be connected.
  • -359 e-Sense Detect with absence dampening for other light sources. More slave luminaires can be connected.
  • -439 e-Sense Detect for LED driver, absence dampening 100–10–0 %

Suffix code e-Sense Move

  • -431 Luminaire with integrated e-Sense Move unit on/off only.
  • -432 Luminaire with integrated e-Sense Move unit for dimming.
  • -440 e-Sense Move for LED driver, absence dampening 100–20–0 %.

 

The sensor/sensor unit is installed differently, depending on the luminaire design. In luminaires with a Beta louvre, the sensor is usually placed in the louvre. Other louvre options have the sensor/sensor unit located in the luminaire body.