fagerhult_classroom_lesson_hero.jpg

Norm on vaid algus – kui lisaks veidi valgust?

Õige valgustus on nägemisülesannete täitmiseks ja keskendumiseks hädavajalik. Valgustid, mis suunavad otsest valgust tööpinnale ja kaudset lae poole, annavad mitmekesist ja sobivat valgust kogu ruumis.

This solution for classrooms is among the best – and is still an excellent choice. The room has a well-balanced combination of direct light at the work surface and ambient light against the walls and ceiling. The pendant luminaires efficiently distributes the light without glare.

To get high enough light levels, several luminaires in a row is recommended in the classroom. By having several daylight sensors, we can ensure that all students in the room gets enough light – while at the same time reducing energy consumption. To facilitate the teachers work the board is equipped with a separate lighting and the room can be equipped with pre programmed light scenarios.

Products

DTI type 2 Beta

Go to product

Lento

Whiteboard lighting adapted to meet modern demands on lighting. Compact size and with a design that makes Lento compatible with various furnishing styles.

Go to product

Pildil olevat valgustuslahendust kasutati Fagerhulti uurimuses, mis viidi läbi Helsingborgis ning millel põhinevad ettevõtte uurimistulemused. Valgustid Indira Wallwasher ja Indira Indirekt Wallwasher paigaldati koos iTrack siinisüsteemiga piki ruumi nelja seina.

Indira Wallwasher annab vertikaalselt valgust klassi eesseinale. Indira Indirekt mudelit kasutatakse ruumi pikemate seinte ääres, kus need suunavad valguse vertikaalselt mööda seina alla ning ka lae suunas. Kui klassiruumis paigutatakse sageli laudu-toole ümber või kasutatakse ruumi tihti praktilise õppe tarvis nt fotograafia- või käsitöökursustel, saab Indira Wallwasheri paigutada ka tagaseinale. Nii on ruumisolijail alati piisavalt valgust, ükskõik mis suunas nad parajasti vaatavad. 

Võrdluseks on esitatud  traditsiooniliste T5  lampidega lahendus, mis näitab, et Indira võimaldab oluliselt kõrgemat valgustustaset.

Products

Indira Indirect

A luminaire with an uplight function where the light is directed at the ceiling. Used as a supplement or mounted in a T solution for smaller classrooms. Using indirect light distribution, the whole room can be lit with no glare.

Go to product

Indira Indirect/Wallwasher

A luminaire with combined wallwasher and uplight function. Mounted in connection with the classroom’s side walls. Using indirect light distribution, the whole room can be lit with no glare.

Go to product

Indira Wallwasher

A luminaire where the light is directed at the wall. Mounted in connection with the classroom’s front and back walls. Using indirect light distribution, the whole room can be lit with no glare.

Go to product

Smaller classrooms up to six metres wide can be illuminated using Indira in a T solution. The iTrack rail mounted in a T formation using Indira Wallwasher directed at the front wall and Indira Indirekt in the middle. Indira Wallwasher provides vertical light on the front wall while Indira Indirekt lights the ceiling.

Products

Indira Indirect

A luminaire with an uplight function where the light is directed at the ceiling. Used as a supplement or mounted in a T solution for smaller classrooms. Using indirect light distribution, the whole room can be lit with no glare.

Go to product

Indira Wallwasher

A luminaire where the light is directed at the wall. Mounted in connection with the classroom’s front and back walls. Using indirect light distribution, the whole room can be lit with no glare.

Go to product

If you wish a ceiling with a cleaner look you can work with a recessed solution. Worth thinking about is that you should move out of the fixtures further out towards the walls to get more light on the walls. Even in this solution, it is important to supply board lighting without glare.

A recessed solution should also have installed lighting controls, such as an e-Sense solution to control the various rows of luminaire separately and also create different lighting scenes for different applications or AV light. Just as in all work areas a fitting without glare is recommended.

Näpunäiteid

Sisevalgustusstandardis EN 12464-1 sätestatakse nüüdsest ka seinte ja lagede valgustamise nõuded. Fagerhult usub, et see on põhjendatud samm. Ent kui tahame ammutada valgusest kogu selle positiivset mõju, on vaja rohkem, kui seadus nõuab.

Ümbritseva valguse kõrge tase teeb erksamaks ja suurendab töövõimet

Valgustus aitab keskenduda ning on nägemisülesannete täitmiseks hädavajalik. Vähesed õpilased veedavad aga kogu päeva vaid oma töölauda jõllitades. Pidev suhtlus õpetaja, teiste õpilaste ja tahvli või interaktiivse ekraaniga tähendab, et pilk rändab ruumis ringi ja fookus muutub alatasa. Kontrastid selle vahel, kuidas on valgustatud tööpinnad, seinad ja lagi, nõuavad aga silmadelt pingutust ja mõjuvad väsitavalt.

Loe lähemalt uurimuse kohta

Rohkem valgust lakke ja seintele

Valgustid, mis annavad valgust nii otse tööpinnale kui ka lakke, tagavad mitmekesise sobiva valgustustaseme kogu ruumis. Vertikaalne valgus tihedusega 300 luksi annab parajat ümbritsevat valgust. Seda täiendab sama tihedusega kaudne valgus, mis on suunatud lakke. Selline lahendus muudab õpilased erksamaks ja soosib nende õpivõimet.

Valgus tööpinnal

Valgustist langeva otsese valguse tihedus on 500 luksi. See on vajalik selleks, et tööpinnal oleks nägemisülesannet võimalikult lihtne sooritada. Lugemiseks on oluline, et valgus oleks ühtlane, praktilised ja keerukad ülesanded aga nõuavad juba kõrgemat valgustustaset.

Valgustus tahvlil

Et tahvlile kirjutatut või sellel kujutatut oleks lihtne näha, on minimaalne valgustustihedus standardi kohaselt 500 luksi. Valgustus peaks siin kindlasti olema kohandatav vastavalt vajadusele.

Ruumis, kus toimub palju visuaalset kommunikatsiooni, jälgi ka silindrilist valgustustihedust.

Silindriline valgustustihedus mõjutab eelkõige visuaalset kommunikatsiooni ja võimet näha nägusid, tegevusi ja objekte. Standard näeb sellistes ruumides ette miinimumvalgustuseks 150 luksi.

Kohanda valgustust vastavalt ülesandele

Kui nägemisülesanne on seotud disaini ja värvidega, on valgusallika puhul oluline selle värviedastusvõime. Üldiselt peaks värviedastusindeks olema vähemalt Ra 80, ent fotograafiaga seotud nägemisülesannete puhul on eelistatav Ra 90.

Et valgus ei pimestaks

Valgustid peavad sobima tööks monitoridega, vältima segavate peegelduste tekitamist ning mitte mõjuma pimestavalt. Ühe ja sama ülesande täitmiseks vajavad noored vähem valgust kui vanemad inimesed. Vananedes suureneb ka inimeste tundlikkus räigele valgusele, mistõttu peavad täiskasvanute koolitusruumid olema eriti läbimõeldult valgustatud.

Valgustuse juhtimine

Fagerhulti juhtmeta juhtimissüsteem e-Sense Connect on mõeldud kasutamiseks haridusasutustes. Paigaldamise ja kasutajafunktsioonide puhul on peetud olulisimaks lihtsust.

Lähemalt e-Sense Connectist

Päevavalgus- ja kohalolekuandur igas valgustireas kohandab valguse sobivaks kogu ruumis. Kui ruumis kedagi ei ole, lülitub valgus välja ja lähtestatakse automaatselt.

Kasutusalad