Indigo Combo Delta 1-cell

Installation
Luminaire for recessed installation in ventilated or unventilated suspended ceilings. Two optional designs.
VTB – for suspended ceilings with visible T-bars 25 or 15 mm.
HB – for suspended ceiling with concealed T-bars. Ceiling type plasterboard, suspended ceilings with edge framing type C or D and for metal tile suspended ceilings. Four fixing brackets are supplied for luminaire type HB.
Luminaire with emergency lighting must not be covered with insulation.

Connection
The luminaire is equipped with a 2.4 m mains cable and earthed plug. Luminaires for dimming are delivered with 5-core, free cable tails, 5-way snap-in terminal block 2.5 mm². Can also be equipped with quick connection system Linect.

Design
Body and reflector of white enamelled sheet steel (RAL 9016) structured finish.

Louvre
Delta – micro-prism louvre in acrylic TPb (PMMA). Frame with louvres remains attached when opened.

Reflector
White enamelled sheet steel.

Dimming
Most models can also be equipped with other ballasts for dimming.

Miscellaneous
Indigo Combo is designed to conform to EN 12 464-1 in its most relevant outputs. Limited average luminance is documented as LL (Luminaire Luminance).

Environment images


Details


Visible part of louvre frame in anodised aluminum.

Visible part of louvre frame in anodised aluminum.

Marking of product sheet

Document added to your cart

Text som beskriver tabellen
W Weight, kg Comment Art.No.
FDH
Module 300x1200, HB
1x25/28 7.1 24915
1x50/54 7.1 24917
2x25/28 7.2 24916
Module 300x1200, VTB
1x25/28 7.1 24910
1x50/54 7.1 24912
2x25/28 7.2 24911
Module 600x600, HB
2x13/14 7.3 24918
2x13/14 7.3 Linect (3-way) 24918-420
2x20/24 7.3 Linect (3-way) 24919-420
2x20/24 7.3 24919
Module 600x600, VTB
2x13/14 7.3 24913
2x13/14 7.3 Linect (3-way) 24913-420
2x20/24 7.3 Linect (3-way) 24914-420
2x20/24 7.3 24914
Text som beskriver tabellen
W Weight, kg Comment Art.No.
FDH
Module 300x1200, HB
1x25/28 7.1 24915-368
1x50/54 7.1 24917-368
2x25/28 7.2 24916-368
Module 300x1200, VTB
1x25/28 7.1 24910-368
1x50/54 7.1 24912-368
2x25/28 7.2 24911-368
Module 600x600, HB
2x13/14 7.3 24918-368
2x13/14 7.3 Linect (5-way) 24918-421
2x20/24 7.3 24919-368
2x20/24 7.3 Linect (5-way) 24919-421
Module 600x600, VTB
2x13/14 7.3 24913-368
2x13/14 7.3 Linect (5-way) 24913-421
2x20/24 7.3 24914-368
2x20/24 7.3 Linect (5-way) 24914-421
Text som beskriver tabellen
W Weight, kg Comment Art.No.
FDH
Module 300x1200, HB
1x25/28 7.1 24915-436
1x50/54 7.1 24917-436
2x25/28 7.2 24916-436
Module 300x1200, VTB
1x25/28 7.1 24910-436
1x50/54 7.1 24912-436
2x25/28 7.2 24911-436
Module 600x600, HB
2x13/14 7.3 24918-436
2x20/24 7.3 24919-436
Module 600x600, VTB
2x13/14 7.3 24913-436
2x20/24 7.3 24914-436

Fluorescent lamp T5, FDH

Art.No.
14, 4000, G5, Ra>80, 1200, 96 81347
28, 4000, G5, Ra>80, 2600, 104 81349
14, 3000, G5, Ra>80, 1200, 96 81351
28, 3000, G5, Ra>80, 2600, 104 81355
24, 3000, G5, Ra>80, 1750, 89 81372
54, 3000, G5, Ra>80, 4450, 93 81374
24, 4000, G5, Ra>80, 1750, 89 81376
54, 4000, G5, Ra>80, 4450, 93 81378

Lined diffuser

Lined diffuser. LL < 1500 cd/m2. Means that the luminaire has been measured and the figure is below the requirement of average luminance acording to EN 12 464-1.

Art.No.
Lined diffuser for module 600. 91645
Lined diffuser for module 1200. 91646

Perforated diffuser

Perforated diffuser. LL < 1000 cd/m2. Means that the luminaire has been measured and the figure is below the requirement of average luminance acording to EN 12 464-1.

Art.No.
Perforated diffuser for 600 module. 91590
Perforated diffuser for 1200 module. 91591

T5 Eco, FDH

Art.No.
13, 3000, G5, 1070, 104 81625
13, 4000, G5, 1070, 104 81626
20, 3000, G5, 1650, 99 81627
20, 4000, G5, 1650, 99 81628
25, 3000, G5, 2450, 114 81629
25, 4000, G5, 2450, 114 81630
50, 3000, G5, 4400, 102 81635
50, 4000, G5, 4400, 102 81636
Dimensions picture
2x20/24 W

2x20/24 W

1x50/54 W

1x50/54 W

2x13/14 W

2x13/14 W

2x25/28 W

2x25/28 W

1x25/28 W

1x25/28 W

Contact us

Contact us